Sterling Plumbing 76090110 Outdoor Shower User Manual


 
Technical Information
Fixture*: basin area top area
Bathing well 44 (111.8 cm) x
16 (40.6 cm)
56 (142.2 cm) x
23-1/2 (59.7 cm)
To overflow water depth capacity
12 (30.5 cm) 34 gal (128.7 L)
* Approximate measurements for comparison only.
Pump: Hp V Hz A
1-speed 1-1/4 120 60 7
Model door maximum
width
door maximum
height
76090110
76090120
58-1/2 (148.6 cm) 56-1/2 (143.5 cm)
76091110
76091120
58-1/2 (148.6 cm)* N/A*
* Varies with alternative walls.
Required Electrical Service
Dedicated circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump 120 V, 15 A, 60 Hz
Installation Notes
Install this product according to the installation guide.
Pump is supplied with a grounding-type plug-in cord. Locate
the outlet behind the whirlpool, and within 24 (61 cm) of the
pump.
Pump access opening is required.
Do not disassemble the pump or piping as this could void the
warranty.
Size the drain cutout to fit the drain assembly that will be
used.
Stud positioning is critical.
Studs should be positioned roughly as shown for support clip
or roofing nail installation.
73-1/2"
(186.7 cm)
1-1/2"
(3.8 cm)
54"
(137.2 cm)
1-1/2"
(3.8 cm)
1-1/2"
(3.8 cm)
31-1/2"
(80 cm)
3" (7.6 cm)
30" (76.2 cm)
19"
(48.3 cm)
18"
(45.7 cm)
15" (38.1 cm)
60" (152.4 cm)
2" (5.1 cm)
D. Drain
60" (152.4 cm) Min
60-1/8" (152.7 cm) Max
Pump
Motor
Location
Access
Opening
3-1/2"
(8.9 cm)
14-1/4"
(36.2 cm)
31-1/2"
(80 cm)
6" (15.2 cm)
(Typical)
14"
(35.6 cm)
8"
(20.3 cm)
8"
(20.3 cm)
22-1/4"
(56.5 cm)
8-3/4" (22.2 cm)
30" (76.2 cm)
16" (40.6 cm)
4" (10.2 cm)
Recommended Support
Clip or Roofing Nail
Location (5 total)
Drain Cutout
76090120
18" (45.7 cm) W
x 15" (38.1 cm) H
Access Panel
2-3/4" (7 cm)
Overflow Detail
Product Diagram
ACCLAIMTM
ACCLAIMTM 60 (152.4 cm) BATH/SHOWER WHIRLPOOL SYSTEM
Page2of2
1016903-4-
F