NOTE: No choke is required on wa_n ehginex. Mike
surechoke isin the "NO CHOKE" posRIon on warm
engine atal_,
[ I_KM,_UlIII[II¢I ¢ou Mus'r unplug any load
I lmll_lll:l from the geosr_or before
| tarring to prevent pern-4nent damage Io any
I applisn©es.
For electric start:
Plaoe OFFIRUN/START sw)tsh in the START
position.
NOTE: When the engine starl_ the switch will
remain in the RUN position.
F_ rm=_ sta_'.
Place OFFIRUN/STARI" switch in the RUN posi-
tion.
STOPPING ENGINE
• Dlscoonect all elecffical loads.
* "nJrrlOFF/RUN/START switoh to 'oFF" position.
Cle=mfuel shut-off valve.
indoors, or in enclosed, poorly ventilated orees or
I
where fuel fum_ may reach an open {lame.
Grasp handle on rope starter lind pull slowly until
roslatance isfelt. Let the rope rewind slowly. Pull
rope with a rapid full arm stroke. Let rope rewind
slowly. Repeat if necessa W,
NOTE: IF ENGINE OIL LEVEL IS TOO LOW, EN-
GINE WILL NOT START. CHECK OIL LEVEL AND
ADD IF NECESSARY,
When engine warms up, gradually push choke
control In to the N° CHOKE posit!on.
IMPORTANT: Allow generator to run at no load
for 5 minutes upon eilch Initial start-up to allow
I
engine end generator to stabilize,
CONNECTING ELECTRICAL LOADS
• Lat onglne mn and warm up for five minutes after
aterdng with noelectrical lead.
COnnect loads in the following manner to prevent
damage to equipment:
• Connect inductive IoQdequipment first, inductive
loads oon_;at of refrigerators, freezers, water
pumps, air conditionem, or small handtoots.
Connect the items that requirethe most wattage
first.
• Connect the lights next.
Voltage sensitive equipment should be the last
equipment oonnectad to the generator. Plug
voltage sensitive appliances such at TV's, VCR's.
mi_rowavos, over.s, oomputem, and cordless
telephones into a UL listed voltage surge protec-
tor, then oonne_t the UL Ilstad voltage surge
protector to the genmtor.
IMPORTANT: You should always add up the rated
watts of all lights,tools and appllan_s you are
powedng at one tim, Thistotal should not
exceed the rated oapacPffof you generator or
olmuit breaker rating of the receptaole supplying
power.
15 --L:NG O_4Nq,_oul_