S-Cam CS1000.22 Pressure Washer User Manual


 
Shut-down procedure
1. Turn off the power switch on the pressure washer.
2. Relieve pressure on line by pulling trigger gun.
3. Shut off water supply and disconnect garden hose.
4. Be sure to check for water leaks or oil leaks that should be repaired before the next oper-
ation.
5. If you are going to store the machine for extended periods of time in cold climates be sure
to anti-freeze the equipment. A 50% anti-freeze solution may be drawn in through the inlet
of the pump using a short remnant of garden hose. This fluid should be run through the
pump. When the fluid is discharged from the pump discharge your machine is winterized.
Do
not allow machine to freeze.
The pump oil should be changed after the first 50 hours of operation. Then change every
year after that for average use. Oil should be changed more frequently for extensive use or
use in dusty areas or areas with high moisture.
Water filters, hoses, and fittings should be checked prior to every operation for cleanliness,
leaks, and needed repair or replacement.
Storage
Pump
Filters
Shut-down