Saunatec 1108-46 Hot Tub User Manual


 
Installation & Operation Instructions
4211-86-G 09-23-05
6
314 SKLH 20C
SECTION 7: OPERATION
For health and fire safety, never attempt to alter or bypass the controls.
This heater has a 60 minutes timer built into the programming. The rock
temperature is preset by the manufacture.
Turning system on:
Position the O - I (On/Off) rocker switch on the lower front of heater to
the “Up” position. This switch can remain in the “I or On” position
indefinitely. The “I” position puts the hand held control in the standby
mode.
Control button names are listed in Diagram 4.
Initializing System: Press the “Reset” two or three times to cycle the
control until the “0” is the only thing glowing in the Boost Power Time
Indicator Lights. This means that the “Boost Power” is set for “0” min-
utes and the “Continuous Power” is “Off”. Press the “Reset” button
again and the control will be in the Standby mode.
To activate “Continuous Power” press the Continuous Power Arrow
“>” on lower half of control. Pressing this button will cycle through the
Continuous Power settings from 100 Watts to 200 Watts and then to 300
Watts. Press the button again and it will turn them off.
Reset
A Boost Power On Lights
B Boost Power Time Indicator Lights
C Increase Boost Power Time Arrow
D Decrease Boost Power Time Arrow
E 100 Watt Indicator Light
F 200 Watt Indicator Light
G 300 Watt Indicator Light
H Continuous Power Arrow
I Reset Button
Diagram 4
A
B
D
E
H
C
F
G
I
The “Continuous Power” is used to replenish the rock temperatures during non sauna use. The lid should be
closed and the heater would use the chosen Continuous Power setting to heat the rocks to normal operating
temperature and the internal thermostat would regulate the temperature. The higher the Continuous Power
setting, the quicker the rocks would regain temperature and be ready to be used again. Refer to “Tips” in Section
6 for more information.
To activate the “Boost Power” press the arrow keys at the top of control to activate the Boost Power timer. As
the arrow “>” key is pressed the time will increase to a maximum of 60 minutes. Press the “<” arrow key and
the time will decrease until 0 minutes.
To activate the “Closed Lid Power” press the “<“ arrow key at the top of the control until the green light is
glowing. This mode will reduce maximum power to continuous power after 3 to 10 minutes when the lid is
closed. When the lid is open, the maximum power will turn back on after 3 to 10 minutes.
The “Boost Power or Closed Lid Power” provide maximum power to the rocks with a maximum time of 60
minutes.
Note: No control functions will be glowing in the Standby mode.