Roberts Gorden CTCU 22 Patio Heater User Manual


 
COMBAT
®
CTCU UNIT HEATERS INSTALLATION OPERATION AND SERVICE MANUAL
8 of 42
SECTION 5: SPECIFICATIONS
5.1 CTCUA (All Models)
Dimension Data - CTCUA (All Models)
Model CTCU-7 CTCU-11 CTCU-15 CTCU-22 CTCU-27 / 32
A
Height
mm
(in)
304
(12.0)
304
(12.0)
450
(17.7)
450
(17.7)
578
(22.8)
B
Mounting Hole Spacing
mm
(in)
239
(9.4)
239
(9.4)
385
(15.2)
385
(15.2)
513
(20.2)
C
Centre of Flue (Top Option)
mm
(in)
151
(5.9)
151
(5.9)
151
(5.9)
172
(6.8)
149
(5.9)
D
Centre of Flue
mm
(in)
68
(2.7)
68
(2.7)
68
(2.7)
46
(1.8)
59
(2.3)
Weight kg 28 30.5 38.5 41 52.3
Rear View
Top View
Air Intake
on Model 22
728
A
Gas Supply
B
171
Lockout Reset
Electrical
Connection
Flue
Air Intake
45
85
D
448
120
End View
660
514
Mounting
Holes
422
Mounting
Holes
448 26514
C
171
120
Air Intake
(Optional Position)
Flue
(Optional Position)
4 x M10 Captive Nuts Provided
463
4 x M10 Captive Nuts Provided
*
* 140 for 27 - 32