MUFFLER
Inspect periodically, the muffler for loose
fasteners, any damage or corrosion. If any sign
of exhaust leakage is found, stop using the
machine and have it repaired immediately.
Note that failing to do so may result in the
engine catching on fire.
SPARK ARRESTER
The muffler is equipped with a spark arrester to
prevent red hot carbon from flying out of the
exhaust outlet. Periodically inspect and clean as
necessary with a wire brush. In the State of
California it is required by law (Section 4442 of
the California Public Resources Code) to equip a
spark arrester when a gas powered tool is used
in any forest covered, brush covered, or grass
covered unimproved land. (MA4)
(1) spark arrester
GEAR CASE
The reduction gears are lubricated by
multipurpose, lithium-based grease in the gear
case. At every 25 hours of use, supply the gear
case with new grease. (MA5)
Remove the cutter holders before installing new
grease to arrange for old grease to exit. (MA7)
When removing and installing the holder(A), use
care not to allow any dirt and dust entering in to
the gear case. (MA7)
DRIVE SHAFT (MA6)
The drive shaft is lubricated by multipurpose
lithium-based grease (NLGI No.2). Pull out the
shaft from the pipe and supply new grease every
50 hours of use or more often depending on the
job condition.
NOTE
WARNING
9. Maintenance
(1)
MA4
MA5
MA6
21