RedMax EBZ8001RH-CA Blower User Manual


 
32
8. Operation
English
exhaust port.
6. Once the engine is running, gradually open the
choke if it was set closed, and let the engine run at
idle speed for a minute to warm it up.
When the engine fails to start after several attempts
due to overchoking, open the choke and repeat pulling
the rope.
ADJUSTING IDLE SPEED (F11)
The idling speed is set for 2000 rpm at the factory. If
it is necessary to adjust the idle speed, use the
adjustment screw on the top side of carburetor.
(1) Idling Adjustment Screw
STOPPING ENGINE
[EBZ8001] [EBZ8001-CA]
Move the throttle lever to the idling position and
press the stop switch (red button). The machine has
the mechanism that once the stop button is pushed
the plug won't give off sparks until the engine stops.
(F12)
(1) Stop Switch
[EBZ8001RH] [EBZ8001RH-CA]
Move the throttle lever to the idling position and set
the ignition switch to the stop position. (F13)
(1) Ignition Switch
If the engine won’t stop when setting the ignition
switch to the stop position, close the choke lever
and stop the engine.
In this case, please repair the machine at your
nealest servicing dealer. (F14)
(1) Choke Lever
(2) OPEN
(3) CLOSE
NOTE
NOTE
(1)
F11
(1)
F12 [EBZ8001] [EBZ8001-CA]
(1)
F13 [EBZ8001RH] [EBZ8001RH-CA]
(1)
(2)
(3)
F14