US-16
EBZ5150/RH
BEFORE STORING THE BLOWER:
1. Drain a fuel tank and push the primer
bulb until it becomes empty of fuel.
2 .Remove the spark plug and drop a
spoonful of 2-cycle oil into the cylider.
Crank the engine several time and
install the spark plug.
3. Store unit in a dry, dust free place, out
of the reach of children.
10. Storage
11. Disposal
• When disposing your machine, fuel or
oil for the machine, be sure to allow
your local regulations.
Case 1. Starting failure
CHECK PROBABLE CAUSES ACTION
fuel tank ➞ incorrect fuel ➞ drain it and with correct fuel
fuel filter ➞ fuel filter is clogged ➞ clean
carburetor adjustment screw ➞ out of normal range ➞ adjust to normal range
sparking (no spark) ➞ spark plug is fouled/wet ➞ clean/dry
➞ plug gap is incorrect ➞ correct (GAP: 0.6 – 0.7 mm)
spark plug ➞ disconnected ➞ retighten
Case 2. Engine starts but does not keep running/Hard re-starting.
CHECK PROBABLE CAUSES ACTION
fuel tank ➞ incorrect fuel or staled fuel ➞ drain it and with correct fuel
carburetor adjustment screw ➞ out of normal range ➞ adjust to normal range
muffler,cylinder (exhaust port) ➞ carbon is built-up ➞ wipe away
air cleaner ➞ clogged with dust ➞ wash
cylinder fin, fan cover ➞ clogged with dust ➞ clean
When your unit seems to need further service, please consult with our service shop in your area.
12. Troubleshooting guide