RedMax EBZ5150 Blower User Manual


 
US-16
EBZ5150/RH
BEFORE STORING THE BLOWER:
1. Drain a fuel tank and push the primer
bulb until it becomes empty of fuel.
2 .Remove the spark plug and drop a
spoonful of 2-cycle oil into the cylider.
Crank the engine several time and
install the spark plug.
3. Store unit in a dry, dust free place, out
of the reach of children.
10. Storage
11. Disposal
When disposing your machine, fuel or
oil for the machine, be sure to allow
your local regulations.
Case 1. Starting failure
CHECK PROBABLE CAUSES ACTION
fuel tank incorrect fuel drain it and with correct fuel
fuel filter fuel filter is clogged clean
carburetor adjustment screw out of normal range adjust to normal range
sparking (no spark) spark plug is fouled/wet clean/dry
plug gap is incorrect correct (GAP: 0.6 – 0.7 mm)
spark plug disconnected retighten
Case 2. Engine starts but does not keep running/Hard re-starting.
CHECK PROBABLE CAUSES ACTION
fuel tank incorrect fuel or staled fuel drain it and with correct fuel
carburetor adjustment screw out of normal range adjust to normal range
muffler,cylinder (exhaust port) carbon is built-up wipe away
air cleaner clogged with dust wash
cylinder fin, fan cover clogged with dust clean
When your unit seems to need further service, please consult with our service shop in your area.
12. Troubleshooting guide