RedMax EBZ5100RH-CA Blower User Manual


 
BEFORE STORING THE BLOWER:
1. Drain a fuel tank and push the primer bulb until it
becomes empty of fuel.
2 .Remove the spark plug and drop a spoonful of 2-
cycle oil into the cylider. Crank the engine several
time and install the spark plug.
3. Store unit in a dry, dust free place, out of the reach
of children.
42
9. Maintenance
English
Air Gap:
0.40mm (0.35 ~ 0.45mm)
0.016" (0.014 ~ 0.017")
(1) Rotor (2) Ignition coil
SHOULDER STRAP
If the shoulder strap is damaged it may break during
use, thus causing the product to fall and resulting in
personal injury. Follow the instructions below to
replace the shoulder strap with new one.
Pass the upper end of the strap through the hanger,
making the FLAPPED SIDE OUTSIDE.
Put the end of the strap through the ring on the
strap, and then push the ring toward the hanger as
close as possible.
(1) Ring
The flap on the end of the strap works as a stopper.
Never install the strap with the flapped side inside,
or the unit may fall from the operator, which could
result in injury to the operator and/or damage to
the unit.
Do not apply liquid type screw lock glue on screws
or bolts used to fix plastics components.
Adherence of this type of glue may cause cracks
on plastics and end up with the breakage.
IMPORTANT
WARNING
10. Storage
English
F23
F22
11. Disposal
English
When disposing your machine, fuel or oil for the
machine, be sure to allow your local regulations.