RedMax EBZ5100 Blower User Manual


 
36
9. Maintenance
English
CLEANING AIR FILTER:
1. Remove the air cleaner cover by pulling the tab on
bottom and take out the filter element.
2. Use neutral detergent and warm water to clean the
filter element. After cleaning, air dry the element
completely and moisten with a small amount of 2
cycle motor oil.
Do not apply 4cycle motor oils as they may damage
element.
Do not use mixture gasoline. This type of gasoline
does not contain much of oil so that the element
becomes dry after a few hours.
(1) 2 Cycle Motor Oil
Soak the filter element into a 2cycle motor oil. Squeeze
the element to remove excess oil so that it weighs 2 to
3 times heavier than that of the dry element.
3. Place the filter element into the packing. Set the
packing into the air cleaner body. Set the cover with
2 fixing screws.
(1) Cover Cleaner (2) Screen
(3) Cleaner Body (4) Element
(5) Packing
Assure that the screen is securely fitted to the
packing. Fit securely if it is loose.
Insufficient fixing of screws may cause fall off of the
cover and insufficient sealing.
Place the filter element into the packing. Set the
packing into the air cleaner body. Set the cover with 2
fixing screws.
IMPORTANT
NOTE
NOTE
NOTE
F14
F15
(1)
(2)
(3)
(5)
(4)
F16