Poulan PPB200 Trimmer User Manual


 
9
ON/OFF
Switch
HOW TO START YOUR UNIT
WARNING: Avoid any contact with
the muffler. A hot muffler can cause serious
burns.
HELPFUL TIP
If your engine still does not
start after following these
instructions, please call
1--800--554--6723.
STARTING A COLD ENGINE (or a
warm engine after running out of
fuel)
Starting Position
Muffler
Choke
Lever
Starter Handle
Primer Bulb
1. Set unit on a flat surface.
2. MoveON/OFF switch tothe ON position.
3. Slowly press the primer bulb 6 times.
4. Move choke lever to FULL CHOKE by
aligning lever with position shown on de-
cal (see illustration below).
Choke
position
decal
5. Squeeze the throttle trigger fully and hold
through all remaining steps.
6. Pull starter rope handle sharply until en-
ginesounds asif itis tryingto start, butdo
not pull rope more than 6 times.
7. As soon as enginesounds as ifit istrying
to start, move choke lever to HALF
CHOKE by aligning lever with position
shown on decal (see illustration below).
Choke
position
decal
8. Pull starter rope sharply u ntil engine runs,
but no more than 6 pulls. If the engine
doesn’t start after 6 pulls (at the HALF
CHOKE position), move the choke lever to
the FULL CHOKE position and press the
primer bulb 6 times. Squeeze and hold the
throttle trigger and pull the starter rope 2
m ore times. Mo ve th e chok e le ver to t he
HALF CHOKE position and pull the starter
rope until the engineruns, but no morethan
6 pulls. If the engine doesn’t start, repeat
procedure 2 additional times.
NOTE: I f engine still doesn’t start, it is
probably flooded. Proceed to ST ARTING A
FL OODE D E NGI NE.
9. Once theengine starts,allow i t torun 10se-
con d s, then mo ve the cho ke leve r to OFF
CHOKE by align ing le ver with p osition
shown on decal (see illustrati on below). Al-
low the unit to run for 3 0 more seconds at
OFF CHOKE before releasing the throttle
trigger.
NOTE: If engine dies with t he
choke lever in the OFF CHOKE position,
mo vethechokele ve rto t he HAL FCHOKE
position and pull the rope until engine runs,
but no more than 6 pulls.
Choke
position
decal
STARTING A WARM ENGINE
1. Move ON/OFF switch tothe ON position.
2. Move the choke lever to the HALF
CHOKE position.
3. Squeeze and hold the t hrottle trigger.
Keep throttle trigger fully squeezed until
the engine runs smoothly.
4. Pull starter rope sharply u ntil engine runs,
but no more than 5 pulls.
5. Allow engine to run 15 seconds, then
movethe chokelever tothe OFFCHOKE
position.
NOTE: If engine has not started, pull starter
rope 5more pulls.Ifenginestilldoes notrun,it
is probably flooded.
STARTING A FLOODED ENGINE
Flooded engines can be started by placing
the choke lever in the OFF CHOKE position;
then, pull the rope to clear the engine of ex-
cessfuel.Thiscouldrequirepullingthestarter
handle many times depending on how badly
the unit is flooded.