Rev. C 11-1-01 P/N 471593
9
• Three-wire remote:
a) Using 3/16" female quick disconnect connectors, connect the common wire to the "GND" tab of the
temperature controller, then connect the two remaining wires to the temperature controller
corresponding to the remote control device, pool wire to "POOL" tab, spa wire to "SPA" tab.
b) Now return power to the heater. (Note: If you used the main power switch to turn off the heater, now
turn the main power switch on.) At this time, the remote system has control over the heater and if pool
or spa temperature is below the temperature controller setting, then the heater will try to come on.
c) If you desire to reset the temperature settings of the temperature controller, the remote has to be in the
desired mode for you to change the particular setting. Example: You wish to raise or lower the pool
temperature from the factory setting, you must have the remote system in the pool mode, if you wish to
change the spa temperature, you must have the remote system in the spa mode.
5. Now turn on the gas valve to "OPEN" position, the heater is now ready to
operate.
NOTE
The heater factory settings are 78° F. for the pool and 104° F. for the spa.
When connecting a remote control to the MiniMax, you must install the low
voltage thermostat wires in separate conduit from ANY line voltage wires.
Failure to follow these instructions will cause the thermostat relay to react
erratically. A Remote hook-up deactivates the selector keys on the front
thermostat display panel and gives selection control to the remote.
TWO-WIRE OR THREE-WIRE REMOTE HOOK-UP, (cont’d.)
Installation (Remotes)
10 A
25O V
RELAY
5 A
25O V
RELAY
10 A
25O V
RELAY
TPROBE
AUX2
POWERLIMITSG VALVEIGN MODULE
24 V
A
C
PV
PV/MV
MV
PV/MV
P
V
MV
24 VAC
H LIMIT
T FU
S
E
PRESS
BLOWER
A.C LOAD (PUMP/AUX2)
(PILOT DUTY ONLY)
3
4
1234 123 123456 12
12
1
2
3
1
F
2
TEMPERATURE
DISPLAY MODE
POOL
3
C
5 A FUSE
FOR AUX2 (PILOT DUTY ONLY)
2
1
3
(AUX1)
REMOTE
AIR PRESS
POOL
SPA
GND
POOL
SPA
GND
BLOWER (POWER) LINE
BLOWER (POWER) LINE
PUMP/AUX2
PURGE
PUMP
MODE
135
642
531
246
J1
J2
REMOTE POOL/OFF/SPA
THERMOSTAT SELECT SWITCH
}NOT USED
COMMON
SPA
3 WIRE REMOTE
This icon is not a fault icon
but instead indicates a remote
switching device is connected
to the Pentair Temperature
Controller 7800, and has
overriding selection control
of Pentair Temperature
Controller 7800.
Figure 8.