Multiquip GAC2.2H Portable Generator User Manual


 
PAGE 22 — GAC2.2H 60 HZ GENERATOR• OPERATION AND PARTS MANUAL — REV. #1 (03/31/10)
OPERATION
8. Place main circuit breaker (Figure 14) in the ON
position.
Figure 14. Main Circuit Breaker (ON)
9. Read the voltmeter on the front panel of the generator
(Figure 15) and verify that 120 VAC is present at the
GFCI duplex receptacle. For additional verification of
voltage, an external voltmeter can be used to measure
the output voltage as shown in Figure 15.
Figure 15. 120V/GFCI Receptacle
10. Connecting of loads (power tools, lighting ect.) to the
generator receptacles can now be done.
Stopping the Engine (Normal Shutdown)
1. Place the main circuit breaker (Figure 16) in the OFF
position.
Figure 16. Main Circuit Breaker (OFF)
2. Let the engine run at idle with no load for 2-3 minutes.
3. Place the engine ON/OFF switch (Figure 17) in the
OFF position.
Figure 17. Engine ON/OFF Switch (OFF)
4. Place the engine fuel valve lever (Figure 18) in the OFF
position.
Figure 18. Engine Fuel Valve Lever (OFF)
5. Remove all loads from the generator.
Emergency Shutdown
1. Place the engine ON/OFF switch (Figure 17) in the
OFF position.