Multiquip EGC-500C Portable Generator User Manual


 
500kW Containerized
Diesel Generator Set
Lubrication System
Type Full Pressure System
Oil Filters Spin-on, Full Flow
Oil Pan Capacity 22 gal. (83.0 L)
Oil Capacity with Filters 24 gal. (91.0 L)
Oil Pressure at Rated Speed (minimum) 20 psi (138 kPa)
Exhaust System
Exhaust Temperature at Rated kW 875
o
F (468
o
C)
Exhaust Flow at Rated kW 3200 cfm (90.6 m
3
/min)
Silencer Type Critical
Maximum Allowable Backpressure (standby) 40.2 in/wc (10 kPa)
Exhaust Outlet Size at hook-up 5.0 in. (127 mm)
DGC-2020 Digital Genset Controller
Local and Remote Generator Control
Automatic and manual starting and stopping
Engine and Generator Protection
Programmable Analog Engine Senders
ECU Communications via SAE J1939
16 Programmable Contact Inputs
Programmable Logic
Automatic Transfer Switch Control (Mains Failure)
Integrated RS485
Auto Synchronizing
Event recording
Monitoring
Engine RPM
Engine run time
Generator voltage
Generator current
Generator frequency
Oil pressure
Battery voltage
Fuel level measurements
Running Hour Meter
Coolant temperature
Generator under/over voltage alarm/shutdown
Generator under/over frequency alarm/shutdown
Over Current alarm/shutdown
Warm up and cooling functions
Maintenance timer
Digital Controller Features
Cooling System
Exhaust Manifold Type Dry
Radiator Design Standard horizontal discharge
Coolant Capacity - Engine 6.3 gal. (24 L)
Water Pump Design/Type Belt Driven, Centrifugal
Coolant Flow 87 gal/min (329 L/min)
Heat Rejection to Coolant 7830 BTU/min (138 kW)
Minimum Pressure Cap 10 psi (70 kPa)
Thermostat Range 180-200 °F (82-93 °C)
Fuel System
Recommended Fuel ASTM-D975-No.1 or No. 2-D
Fuel Pump Maximum Lift 6.0 ft. (1.8 m)
Filter Micron Size - 98% Efficiency 2
Total Fuel Flow 112 gal./hr. (424 L/Hr.)
Fuel Tank Capacity 800 gal (3028 L)
Fuel Consumption - gal/hr (L/hr)
Diesel Fuel @ % of Load Standby Prime
25% 11.6 (43.9) 9.9 (37.4)
50% 18.8 (71.1) 17.2 (65.3)
75% 25.7 (97.2) 23.9 (90.5)
100% 34.4 (130.2) 31.1 (117.8)
EGC500C Rev 0