DCA400 SERIES — FUEL RETURN LINE KIT INSTRUCTIONS P/N 35499 — REV. #0 (01/26/11) — PAGE 3
4. Disconnect drain hose from trailer return port. See
Figure 6.
Figure 6. Disconnect Drain Hose
5. Remove fittings from trailer return port. Retain the 90º
fitting, and discard the others. See Figure 7.
Figure 7. Remove Trailer Return Port Fittings
Drain
Disconnect
Drain Hose
Trailer
Return
Port
Trailer
Return Port
Remove
Fittings
Retain
90º Fitting
INSTALL NEW TRAILER RETURN PORT FITTINGS
Refer to Figure 8.
Figure 8. New Trailer Return Port Fittings
1. Install Item 3, tee fitting, into trailer return port.
2. Install Item 2, straight fitting, into the right side of the
tee fitting.
3. Install existing 90º fitting into Item 2. Connect to drain
hose.
4. Install Item 4, straight fitting, into the left side of the tee.
Existing 90º
Fitting
Drain
Hose
2
4
3
NOTICE
Apply pipe sealant to all fittings.