DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07) — PAGE 27
1
Shut Down Codes
1. During normal operation the single or four parameter
screen will be displayed.
2. When the diagnostic display receives a severe fault
code from an engine control unit the single or four
parameter screen will be replaced with the “Shutdown”
message.
3. To acknowledge and “Hide” the fault and return to the
single or four parameter display touch the “Enter Button”.
4. The display will return to the single or four parameter
display, but the display will contain the “Shut Down”
icon. Touching the “Enter Button” will redisplay the hidden
fault.
COOL
1800 RPM
0
1500
3000
TEMP
ENG RPM
98%
14.2
57 PSI
1000 RPM
LOAD RPM
BATTVOLT
ENG RPM
OIL PRES
SPN110 FMI10
HIGH COOLANT TEMP
SHUTDOWN
1ofx
MORE
HIDE
SPN110 FMI10
HIGH COOLANT TEMP
SHUTDOWN
1ofx
MORE
HIDE
COOL
1800 RPM
0
1500
3000
TEMP!
ENG RPM
!
98%
14.2
57 PSI
1000 RPM
LOAD RPM
BATTVOLT
ENG RPM
OIL PRES
!
5. Touching the “Enter Button” once again will hide the
fault and return the screen to the single or four parameter
display.
6. The Single or Four parameter screen will display the
fault icon until the fault condition is corrected. NOTE:
Ignoring active fault codes could result in severe engine
damage.
SPN110 FMI10
HIGH COOLANT TEMP
SHUTDOWN
1ofx
MORE
HIDE
COOL
1800 RPM
0
1500
3000
TEMP!
ENG RPM
!
98%
14.2
!
57 PSI
1000 RPM
LOAD RPM
BATTVOLT
ENG RPM
OIL PRES
!
Backlight Adjustment
1. Starting at the single or four engine parameter display
touch the “Menu Button”.
2. The main menu will pop up on the display. Use the “Arrow
Buttons” to scroll through the menu until the “Adjust
Backlight” is highlighted.
COOL
1800 RPM
0
1500
3000
TEMP
ENG RPM
98%
14.2
57 PSI
1000 RPM
LOAD RPM
BATTVOLT
ENG RPM
OIL PRES
GO TO 1-UP DISPLAY
STORED CODES
GENGINE CONF
SETUP 1-UP DISPLAY
SETUP-4-UP DISPLAY
SELECT UNITS
ADJUST BACKLIGHT
DCA-150SSJU3 — DIAGNOSTIC DISPLAY