Multiquip DA7000SSA Portable Generator User Manual


 
PAGE 32 — DA7000 SERIES GENERATORS• OPERATION AND PARTS MANUAL — REV. #5 (01/20/11)
MAINTENANCE
Use Table 8as a general maintenance guideline when
servicing your engine. For more detail engine maintenance
information, refer to the engine owner's manual supplied
with your engine.
Table 8. Engine Maintenance Schedule
DESCRIPTION
(3)
OPERATION DAILY
FIRST
MONTH OR
50 HRS.
EVERY 3
MONTHS
OR 25 HRS.
EVERY 6
MONTHS
OR 50 HRS.
EVERY
YEAR OR
100 HRS.
EVERY
2 YEARS
OR
200 HRS.
EVERY 8
YEARS
OR
800 HRS.
Engine Oil
CHECK X
CHANGE X X
Oil Filter
Cartridge
CHANGE X
Air Cleaner
Element
CHECK X
CHANGE X(1)
All Nuts & Bolts
RETIGHTEN IF
NECESSARY
X
Cooling Fins CHECK X
Fuel Tank CLEAN X
Fuel Filter CLEAN X
Fuel Filter
Element
CHANGE X
Fuel lines CHANGE Every 2 years, replace if necessary (2)
Battery CHANGE X
Radiator Hoses/
Clamps
CHANGE Every 2 years, replace if necessary (2)
Radiator
Coolant
CHANGE X
Idle Speed CHECK-ADJUST X (2)
Valve Clearance CHECK-ADJUST X (2)
(1) Service more frequently when used in DUSTY areas.
(2) These items should be serviced by your service dealer, unless you have the proper tools and are mechanically
profi cient. Refer to the KUBOTA Shop Manual for service procedures.
(3) For commercial use, log hours of operation to determine proper maintenance intervals.
NOTICE
Thoroughly remove dirt and oil from the engine and
control area. Clean or replace the air cleaner elements
as necessary. Check and retighten all fasteners as
necessary..