MTD 24AD598A010 Log Splitter User Manual


 
2 of 3 Form No. 769-05565
INSPECTION PROCEDURE continued
5. Locate the control valve at the operator’s position of the log splitter and look at the control valve end cap (opposite end
from the control handle). See Figure 2.
6. If the valve has the name “ENERGY” on the end cap, as shown in Figure 3, the valve must be tested. Proceed to the
“TEST PROCEDURE” section on Page 3.
If the end cap on the control valve does not have the name “ENERGY” on it, your log splitter is not affected by this recall.
You should stop here.
Control Valve
Control Valve
21 to 33 Ton
8 Ton
End Cap
End Cap
FIGURE 2
FIGURE 3
If you have any questions related to this Inspection and Test Procedure, call
MTD Customer Service toll free at
1-888-848-6038
Monday through Friday
8:00 AM and 5:00 PM Eastern Time
Saturday
10:00 AM to 3:00 PM Eastern Time