Mitsubishi Electronics MGS2500HV Portable Generator User Manual


 
MITSUBISHI MGS SERIES
DIESEL GENERATOR SET
MGS2500HV
Type & Design
MGS standard 7310 programmable microprocessor control-automatic start/stop panel, generator breaker control,
indicating the operational status and fault conditions; automatically shutting down the engine and indicating the engine
failure by means of LCD display and LEDs on the front panel.
Controls & Monitoring
Mode selection & start engine button with interlock key switch system
Menu navigation button
LCD display for: AC amperage-each phase and earth current, AC voltage-each phase and neutral, Frequency Hz,
Operation hours run, Lub. Oil pressure, Cooling water temperature, Generator Load kW/kVA/kVar, Generator Load
kWh/kVAh/kVarh
Operation status LED indicators
CB control buttons
Mute/Lamp test button
Voltage adjuster
Speed adjuster
Emergency stop pushbutton
Provided 5 outputs for status as standard equipment (Programmable 8 outputs available as option)
Safety Shutdown Protection and LED Indicators
High engine temperature, Low oil pressure, Fail to start, Generator Over Speed/Frequency,
Generator Under Speed/Frequency
Generator High Voltage, Generator Low Voltage, Oil pressure sender circuit, Loss of Speed signal , Emergency stop,
Mounting
Fabricated cubicle mounted on individual bracket with anti-vibration isolator
Electrical Design
In accordance with BS EN 60950 Low Voltage Directive, BS EN 61006-2 and 61006-4 EMC Directive. The optional
interface can provide real time diagnostic facilities.
Generator Control Panel Description
3 position operation mode control key switch
(ACTIVE, PANEL LOCK, STOP/RESET)
Manual button Stop/Reset button (Manual only)
Auto button Mute/Lamp test button (Manual only)
CB open button (Manual only) Voltage adjusting trimmer
CB close button (Manual only) Speed adjusting trimmer
Start engine button (Manual only) Emergency stop pushbutton
LCD display accessed by scroll pushbutton
Generator volts L1-N, L2-N, L3-N
Engine cooling water temperature (°C & °F)
Generator volts L1-L2, L2-L3, L3-L1
Battery volts
Generator amps L1, L2, L3
Engine hours run
Generator Earth Current
Generator Load kW, kVA, kVar
Generator Frequency Hz
Generator Load kWh, kVAh, kVarh
Engine speed RPM
Power Factor
Engine oil pressure (PSI & Bar)
Generator Phase Sequence
Visual indicators on LCD display
Shutdown alarm
Generator high current
Warning alarm
Over voltage (AC)
High coolant temperature
Under voltage (AC)
Low oil pressure
Over voltage (DC)
Charge fail
Under voltage (DC)
Over-speed
Auxiliary indication
Under-speed
Auxiliary alarm (warning or shutdown)
Electrical trip
Common alarm
Fail to stop
Over frequency
Under frequency
Visual indication alarm and automatically shutdown
High engine temperature
Over frequency
Low oil pressure
Under frequency
Fail to start
Oil pressure sender open circuit
Over-speed
Loss of speed signal
High voltage
High Crankcase internal pressure (MGS-C Continuous only)
Low voltage
Emergency Stop
Operation status indicated by LED
Remote start present
Lubrication oil filter clogged
Generator ready
Electrical trip
Pre-Programmed Starting Unit
Automatic start/stop sequence timing and delay systems configured
via MS-Windows based software.
MGS SERIES 7310 GENERATOR CONTROL PANEL