Master Lock MGY5000C Portable Generator User Manual


 
9
107359
OWNER’S MANUAL
Running Starting
Equipment Watts Watts
1/2" Drill 1000 1250
Toaster 1200 1200
Coffee maker 1200 1200
Skillet 1200 1200
14" Chain saw 1200 1500
Water well pump
(1/2 hp) 1000 3000
Hot plate/range
(per burner) 1500 1500
10" Table saw 2000 6000
Water heater 5000 5000
Running Starting
Equipment Watts Watts
Light bulb (100W) 100 100
Radio 150 150
Fan 200 600
Television 400 400
Furnace fan
(1/3 hp)
600 1800
Vacuum cleaner 600 750
Sump pump
(1/3 hp)
700 2100
Refrigerator/freezer 800 2400
6" Circular saw 800 1000
Floodlight 1000 1000
Approximate Starting Watts*
Motor Approximate Universal Repulsion Split
HP Running Motors Induction Capacitor Phase
Rating Watts (small appliance) Motors Motors Motors
1/8 500 625 1100 1500 2250
1/4 700 875 1550 2100 3150
1/3 800 1000 1750 2400 3600
1/2 1100 1375 2400 3300 4950
3/4 1400 1750 3100 4200 x
1 1700 2125 3750 5100 x
1
1
/2 2100 2625 4620 6300 x
2 2450 3075 5400 x x
Chart 2
* – Always use starting watts, not running watts, when figuring correct electrical load.
x – Motors of higher horsepower are not generally used.
Chart 1 - Typical Electric Appliance Wattages
DETERMINING
ELECTRICAL LOAD
FOR GENERATOR
Continued
OPERATION
GENERAL INFORMATION
This generator is not large enough to power
your entire home. Do not connect generator
to any existing electrical circuits. Plug items
directly into generator receptacles. Do not
exceed amperage rating of receptacles. Only
use grounded cords.
DANGER: Use only in well-
vented areas. Make sure area has
plenty of free-moving, fresh, out-
side air. Never run generator in
an enclosed or confined area.
Never run generator inside occu-
pied building. Engine exhaust
contains poisonous carbon mon-
oxide gas. Overexposure will
cause loss of consciousness and
will lead to death.
WARNING: Never connect
generator to any existing electri-
cal circuits. The generator out-
put will back-feed into the utility
power line. This may electrocute
a power company line repair per-
son. Also, if generator is power-
ing electrical circuits, the chance
of an electrical fire exists.
Note:
We supply the engine owner’s manual
with generator. Refer to that manual for
questions concerning engine operation.
USING RECEPTACLE
Note:
Do not exceed amperage rating of
receptacles. Exceeding rating will trip re-
ceptacle circuit breaker.
Use receptacles properly. Improper use could
damage generator. Use only grounded exten-
sion cords. Power only grounded or double-
insulated items. Do not overload receptacles.
This generator has the following receptacles
(see Figure 13):
120V, 15-amp duplex receptacle
120V, 15-amp GFCI duplex receptacle
120V, 30-amp twist-lock receptacle
120/240V, 20-amp twist-lock receptacle
Chart to be used as reference. Data may vary wiht size, make, and/or model.
Continued