Makita G351O R Portable Generator User Manual


 
8.
"HOW-TO"
MAINTENANCE
1.
ENGINE OIL CHANGE
Change engine oil every
50
hours.
(for new engine, change oil after
20
hours.)
(a) Drain oil by removing the drain plug and
the oil filler cap while the engine is warm.
(b) Reinstall the drain plug and
fill
the en-
gine with oil until it reaches the upper
level on the oil filler cap.
Use fresh and high quality lubricating oil
to the specified level as directed on
page
5.
If
contaminated or deteriorated
oil
is
used or the quantity
of
the engine oil is not sufficient, the engine damage
will result and its life will be greatly shortened.
2.
SERVICING THE
AIR
CLEANER
t
Maintaining an air cleaner in proper condi-
tion is very important. Dirt induced through
improperly installed, improperly serviced or
inadequate elements damages and wears
out engines. Keep the element clean ac-
cording to the chart on page
21.
PROCEDURE:
(a)
Unhook the cover and remove the
cleaner element.
(b)
Inner element: Wash the element with
kemsene, then soak it in mixed oil
(Kerosene
(3
parts)
:
Engine oil
(1
part)).
Drain the mixed oil.
(c) Outer element: Wash the element with
kerosene, then dip it into the mixed oil
(Kerosene
(3
parts): Engine oil
(1
part)).
Squeeze out the mixed oil. (Do not
twist.)
I
COVER
OUTER
INNER
1
ELEMENT
ELEMENT
-
23
-