" I " (ON)
"
O
" (OFF)
" I " (ON)
"
O
" (OFF)
ON
OFF
Speed control lever
L
H
Speed control lever
3. STOPPING
(a) Set the speed control lever at the
low speed position and allow the
engine to run at low speed for 2 or 3
minutes before stopping. (EW120R)
Set the speed control lever at the
low speed position and allow the
engine to run at low speed for 1 or 2
minutes before stopping.
(EW220R,EW320TR)
(b) Turn the STOP SWITCH to the
position “O” (OFF).
Do not stop the engine suddenly
when it is running at high speed.
(c) Close the fuel cock.
(EW220R,EW320TR)
CLOSE
OPEN