11
– Remove the air cleaner cover.
– Place the control cable (1) in the adjusting bolt (2), and shift the swivel (3) so
that the cable will be put in the swivel groove. At this time, the round-hole
side of the swivel will be oriented toward the inner wire end-metal fitting.
– Release the swivel, and confirm that the inner wire-end metal fitting will be
placed in the hole.
– Mount the air cleaner cover.
CONNECTION OF SWITCH CORD
– Connect the switch cords to the two cords from the engine by inserting one
into the other.
– Fix the cord connector by clamp (4).
ADJUSTMENT OF CONTROL CABLE
Adjust the control cable by adjusting bolt so that it will have 1 to 2 mm play
when the throttle lever is set to the low-speed position by carburetor adjusting
bolt. (Be careful that the cutter blade will not turn in idling.)
፧
MOUNTING OF CONTROL CABLE
፧
Control cable
Swivel
End fitting
Round-hole
(4)
Insert
፧
1-2 mm
፧
(2)
(1)
(3)