INSTR,INSTL,XR-16
LINEAR P/N: 215157 B
MATERIAL: 20 LB. MEAD BOND
SIZE: 8.500" X 11.000"
SCALE: 1-1
INK: BLACK
SIDE 2 OF 2 (BACK)
8. TYPICAL WIRING CONNECTIONS 9. SET OPTION JUMPERS 10. SET SYSTEM CODE 11. SET STATUS OPTIONS
12. SET TRANSMITTER CHANNELS 13. TEST THE SYSTEM 14. EXAMPLE HOOK-UPS LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship
for twelve (12) months. The Warranty Expiration Date is labeled on the product.
This warranty extends only to wholesale customers who buy direct from Linear or
through Linear’s normal distribution channels. Linear does not warrant this product
to consumers. Consumers should inquire from their selling dealer as to the nature of
the dealer’s warranty, if any. There are no obligations or liabilities on the part of
Linear LLC for consequential damages arising out of or in connection with use
or performance of this product or other indirect damages with respect to loss of
property, revenue, or profit, or cost of removal, installation, or reinstallation. All
implied warranties, including implied warranties for merchantability and implied
warranties for fitness, are valid only until Warranty Expiration Date as labeled on the
product. This Linear LLC Warranty is in lieu of all other warranties express or
implied.
All products returned for warranty service require a Return Product Authorization
Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA#
and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need
in portable wireless signaling. However, there are some limitations which must be
observed.
✶ WARNING: THIS PRODUCT IS NOT TO BE USED IN LIFE SAFETY
APPLICATIONS. FCC Rules allow unlicensed high-power transmissions at
or near the operating frequency of this product which may interfere with,
or even disable, normal operation of this radio device.
✶ For U.S. installations only: The radios are required to comply with FCC Rules
and Regulations as Part 95 Radio Control devices. As such, they have limited
transmitter power and therefore limited range.
✶ A receiver cannot respond to more than one transmitted signal at a time and
may be blocked by radio signals that occur on or near their operating
frequencies, regardless of code settings.
✶ Changes or modifications to the device may void FCC compliance.
✶ Infrequently used radio links should be tested regularly to protect against
undetected interference or fault.
✶ A general knowledge of radio and its vagaries should be gained prior to acting as
a wholesale distributor or dealer, and these facts should be communicated to the
ultimate users.
Copyright © 2004 Linear LLC 215157 B
INSTALL END-OF-LINE RESISTORS
IF REQUIRED BY ALARM PANEL
TYPICAL 8-ZONE
ALARM CONTROL PANEL
ZONE 1
COMMON
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
ZONE 8
COMMON
COMMON
COMMON
AUXILIARY
POWER
OUTPUTS PROGRAMMED
FOR NORMALLY OPEN
CH1
CH2
CH3
CH4
GND
CH5
CH6
CH7
CH8
GND
CH9
CH10
CH11
CH12
GND
CH13
CH14
LOW BAT
STS ALM
GND
N/O
N/C
COM
+12 VDC
GND
CH15
CH16
GND
RELAY
XR-16 RECEIVER
ZONE 8 IS BEING USED
TO REPORT TROUBLE
RECEIVER CHANNELS 8-16
ARE UNUSED IN THIS EXAMPLE
EXAMPLE OF
DRIVING A RELAY
FROM XR-16 OUTPUT
NOISEMAKER
ACTIVATED BY
XR-16 RELAY
+
THE XR-16 RELAY OUTPUT CAN BE
PROGRAMMED TO ACTIVATE WITH
ANY SIGNAL OR ONLY ALARM SIGNALS
OUTPUT
OPTION
JUMPER (JP2)
RELAY
OPTION
JUMPER (JP1)
1
2
3
1
2
3
OUTPUT
OPTION
RELAY
OPTION
1 & 2 = ALL OUTPUTS
NORMALLY OPEN
1 & 2 = RELAY WILL ACTIVATE
ON ALARMS & TROUBLE
1
2
3
1
2
3
2 & 3 = ALL OUTPUTS
NORMALLY CLOSED
2 & 3 = RELAY WILL
ACTIVATE ON ALARMS ONLY
OUTPUT
OPTION
RELAY
OPTION
XR-16 RECEIVER
SWITCH "A"
SWITCH "B"
SET SYSTEM CODE SWITCHES "A" & "B" IN THE
RECEIVER TO MATCH SYSTEM CODE SWITCHES
"A" & "B" IN ALL OF THE SYSTEM'S TRANSMITTERS
SYSTEM CODE SWITCHES
AVOID SETTING SYSTEM CODE SWITCHES
ALL "ON", ALL "OFF", OR IN ALTERNATING
"ON"/"OFF" PATTERNS
XR-16 RECEIVER
LEFT DIPSWITCH
SWITCHES 1-8
CHANNELS 1-8
RIGHT DIPSWITCH
SWITCHES 1-8
CHANNELS 9-16
SET STATUS OPTION SWITCHES "ON" FOR EACH
RECEIVER CHANNEL THAT WILL REQUIRE STATUS
REPORTS
STATUS OPTION SWITCHES
ANY CHANNEL WITH ITS STATUS OPTION SWITCH "ON"
WILL EXPECT HOURLY STATUS REPORTS FROM
TRANSMITTERS PROGRAMMED TO THAT CHANNEL
IF STATUS REPORTS ARE NOT RECEIVED FOR THAT
CHANNEL FOR FOUR HOURS, THE STATUS ALARM
OUTPUT WILL ACTIVATE (THE RELAY CAN ALSO
ACTIVATE IF SELECTED)
2
1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
RX
CH. #
BANK 1
BANK 2
BANK 3
BANK 4
TX
CH. #
2
1
3
4
1
2
3
4
1
2
3
4
1
2
3
4
EVERY FOUR RECEIVER CHANNELS CREATE ONE
RECEIVER BANK
SINGLE-CHANNEL TRANSMITTERS:
SET THE RECEIVER CHANNEL NUMBER (1-4) AND
BANK NUMBER (1-4) ON THE OPTION SWITCHES IN
THE TRANSMITTER
MULTI-CHANNEL TRANSMITTERS:
SET THE RECEIVER BANK NUMBER (1-4) ON THE
OPTION SWITCHES IN THE TRANSMITTER
16 RECEIVER
CHANNELS
4 TRANSMITTER
CHANNELS
4 RECEIVER
BANKS
REFER TO THE SPECIFIC TRANSMITTER INSTRUCTIONS
FOR ACTUAL SWITCH "ON"/"OFF" SETTINGS FOR
EACH MODEL OF TRANSMITTER
MEASURE
VOLTAGE
DCV
+ 12 VDC
POWER
INPUT
RCVR
OUTPUT
CHANNEL
NORMALLY OPEN
OUTPUTS WILL SWITCH
TO GROUND WHEN ACTIVE
1. APPLY POWER TO THE
RECEIVER AND TRANSMITTER(S).
THE RECEIVER'S POWER
INDICATOR SHOULD LIGHT AND
DASHES SHOULD MOVE ACROSS
THE DISPLAY.
2. ACTIVATE AND MAINTAIN A
TRANSMITTER INPUT (WITH
AUTO-RESTORE OFF). DISPLAY
SHOULD SHOW THE CHANNEL #
AND AN "A".
4. RESTORE THE TRANSMITTER'S
INPUT. THE CHANNEL # AND THE "A"
SHOULD GO AWAY.
3. VERIFY THAT THE CHANNEL'S
OUTPUT ACTIVATES WHILE THE "A" IS
ON THE DISPLAY. USE A METER OR
CHECK THE CONNECTED DEVICE.
CH5CH1 CH2 CH3 CH4 GND CH6 CH7 CH8
XR-16 RECEIVER
MOOSE Z1100 ALARM PANEL
ZN1
1
COM
2
ZN2
3
ZN3
4
COM
5
ZN4
6
ZN5
7
COM
8
ZN6
9
AUX
POWER
2.2K EOL
RESISTORS
(ZONES PROGRAMMED NORMALLY OPEN)
ZN7
10
COM
11
ZN8
12
28 29
C&K 236 ALARM PANEL
Z1 C Z2 Z3 C Z4 Z5 C Z6
AUX
POWER
AUX
C
+12
VDC
GND
CH5CH1 CH2 CH3 CH4 GND CH6
XR-16 RECEIVER
2.2K EOL
RESISTORS
(ZONES PROGRAMMED NORMALLY OPEN)
+12
VDC
GND
THE XR-16 RECEIVER CAN BE CONNECTED TO COMMON
ALARM CONTROL PANELS OR MANY OTHER EXTERNAL DEVICES