Land Pride RCPM3060 Brush Cutter User Manual


 
47
Section 9: Troubleshooting
12/16/08
RCP2660, RCPM2660, RCP3060 and RCPM3060 Parallel Arm Rotary Cutter 316-111M
Land Pride
Table of Contents
Electrical control push button
switches do not work
10 AMP Fuse broken. Replace 10 AMP fuse
Circular Plastic connector is not connected
to receptacle.
Connect remote cable to solenoid control
valve.
No power to control stick connections. Check battery or power
Tractor spool valve not engaged (open). Lock tractor control valve open.
Flow Control Valve not adjusted properly for
open/closed center tractor
Adjust flow control valve
Hoses not connected to proper duplex outlet
on tractor
Connect hoses to proper tractor outlet.
Defective solenoid on cartridge valve assy. Replace solenoid.
Solenoid valves is sticking. Remove/clean/replace solenoid valve.
Tractor hydraulic fluid level is too low. Add fluid to tractor reservoir.
Problem Cause Solution