Kohler 100EFOZ/125EOZ Portable Generator User Manual


 
TP-6069 6/0314 Section 4 Exhaust System
4.3.2 Mid/Below-Waterline Installation
Follow USCG Regulations for installing an antisiphon
provision to prevent raw water entry into the engine.
Use the siphon break if the exhaust manifold outlet is
located less than 23 cm(9 in.) above the waterline when
the craft is loaded to maximum capacity. Install the
siphon break at least 31 cm (1 ft.) above the waterline
using the instructions provided withthe siphon break kit.
Note: An improperly installed siphon break will cause
engine damage and may void the warranty.
Install the siphon break above the highest point in the
exhaust line between the heat exchanger and the
exhaust mixer. See Figure 4-5 for the siphon break
connection. Support the siphon break and hoses to
maintain their position and function. Allow a slight offset
to clear the stringers or other permanent structures.
Protect the siphon break air inlet from dirt and debris.
Note: Toprevent waterleakage on thegenerator set, do
not mount the siphon break directly over the
generator set.
1
TP-5586-6
1. Cut hose and connect siphon break and hardware
Figure 4-5 Siphon Break Connection (4EFOZ/5EOZ
model shown)
Mounta typical silencer’s base no more than 1.2 m (4 ft.)
below the highest point in the exhaust line. Attach a
separate wood mounting base to the hull stringers or
other suitable structures. Use the silencer
manufacturer’s recommendation for securing the
silencer to the hull. Mount thesilencer withthe outletnot
more than 3 m (10 horizontal ft.) from the engine’s
exhaust manifold outlet. Use a USCG-type certified
marine exhaust hose.