English 5
TURE AND INJURY, DO NOT
OPERATE THIS PUMP WITH COMPO-
NENTS RATED LESS THAN 1850 PSI
WORKING PRESSURE (INCLUDING
BUT NOT LIMITED TO SPRAY GUNS,
HOSE AND HOSE CONNECTIONS).
BEFORE SERVICING, CLEANING OR
REMOVING ANY PARTS, SHUT OFF
POWER AND RELIEVE PRESSURE.
IF CONNECTION IS MADE TO A PO-
TABLE WATER SYSTEM, THE SYS-
TEM SHALL BE PROTECTED
AGAINST BACKFLOW.
This product must be grounded. If it
should malfunction or breakdown,
grounding provides a path of least resis-
tance for electric current to reduce the
risk of electric shock. This product is
equipped with a cord having an equip-
ment-grounding conductor and a
grounding plug. The plug must be
plugged into an appropriate outlet that is
properly installed and grounded in ac-
cordance with all local codes and ordi-
nances.
ƽ DANGER
Improper connection of the equipment-
grounding conductor can result in a risk of
electrocution. Check with a qualified elec-
trician or service personnel if you are in
doubt as to whether the outlet is properly
grounded. Do not modify the plug provid-
ed with the product - if it will not fit the out-
let, have a proper outlet installed by a
qualified electrician. Do not use any type
of adapter with this product.
This pressure washer is provided with a
ground-fault circuit-interrupter (GFCI)
built into the plug of the power-supply
cord. This device provides additional
protection from the risk of electric shock.
Should replacement of the plug or cord
become necessary, use only identical
replacement parts that include GFCI
protection.
ƽ CAUTION
When connecting the water inlet to the
water supply mains, local regulations of
your water company must be observed.
In some areas the unit must not be con-
nected directly to the public drinking wa-
ter supply. This is to ensure that there is
no feedback of chemicals into the water
supply. Direct connection via a receiver
tank or backflow preventer, for example,
is permitted.
Dirt in the feed water will damage the
unit. To avoid this risk, we recommend
fitting a water filter.
Garden hose must be at least 1/2
inch or 5/8 inch in diameter.
Flow rate of water supply must not
fall below 2 GPM (gallons per
minute).
Flow rate can be determined by run-
ning the water for one minute into an
empty 5-gallon container.
The water supply temperature must
not exceed 104°F/40°C.
Never use the pressure washer to
draw in water contaminated with sol-
vents, e.g. paint thinners, gasoline,
oil, etc.
Always prevent debris from being
drawn into the unit by using a clean
water source.
SAVE THESE INSTRUCTIONS!
GROUNDING INSTRUCTIONS
GROUND FAULT CIRCUIT
INTERRUPTER PROTECTION
WATER SUPPLY
(Cold Water Only)