Karcher HDS 1195 Pressure Washer User Manual


 
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295 14
TECHNICAL DATA
Type HDS Super
(1.025)
HDS 695 S * AUS
(1.025-305)
HDS 745
(1.026)
HDS 895 S
(1.027)
Mains connection
420 V
3~ 50 Hz
420 V
3~ 50 Hz
240 V
1~ 50 Hz
110 V
1~ 50 Hz
420 V
3~ 50 Hz
Connected load 6,4 kW 5,6 kW 3,2 kW 3,2 kW 6,8 kW
Fuse (slow blow) 16 A 16 A 16 A 30 A 16 A
Water connection
Supply temperature max.30 °C max.30 °C max.30 °C max.30 °C
Supply volume min. 1200 l/h min. 1000 l/h min. 1000 l/h min. 1200 l/h
Suction height when drawn
from open tank
(at 20°C water temperature)
0,5 m 0,5 m 0,5 m 0,5 m
Performance data
Flow rate: cold/hot water 900-450 l/h 800-400 l/h 700-350 l/h 700-350 l/h 1000-470 l/h
Operating pressure: cold/hot
water
(with standard nozzle supplied)
180-30 bar 150-30 bar 110-30 bar 110-30 bar 180-30 bar
Flow rate: steam 450 l/h 400 l/h 350 l/h 470 l/h
Operating pressure: steam
(with steam nozzle (4.766-023)
max.32 bar max.32 bar max.32 bar max.32 bar
Operating temperature
- Hot water max.90 °C max.90 °C max.90 °C max.90 °C
- Steam 98-155 °C 98-155 °C 98-155 °C 98-155 °C
Cleaning-agent intake 0 - 35 l/h 0 - 32 l/h 0 - 35 l/h 0 - 40 l/h
Burner output 62 kW 62 kW 50 kW 68 kW
Recoil force of
handgun 32 N 32 N 24 N 43 N
Sound level as per
EN 60704-1 79 dB(A) 72 dB(A) 70 dB(A) 72 dB(A)
Vibration of the unit according to
ISO 5349
2,6 m/s² 1,9 m/s² 2,2 m/s² 1,9 m/s²
Fuels
Fuel Fuel oil EL or diesel Fuel oil EL or diesel Fuel oil EL or diesel Fuel oil EL or diesel
Oil quantity 0,6 l 0,75 l 0,75 l 0,75 l
Oil grade Hypoid SAE90 (6.288-016) Hypoid SAE90 (6.288-016) Engine oil 15W40 (6.288-050.0) Hypoid SAE90 (6.288-016)
Dimensions and weights
Length x Width x Height 1285x690x835 mm 1285x690x835 mm 1285x690x835 mm 1285x690x835 mm
Weight not incl. accessories 133 kg 130 kg 130 kg 133 kg
Fuel tank 25 l 25 l 25 l 25 l
Cleaning-agent tank 20 l 20 l 20 l 20 l