John Deere HR-2700GH Pressure Washer User Manual


 
AC-Series Operator’s Manual-E/F 27
A
Service
GASOLINE ENGINE OIL
Use oil viscosity based on the expected air temperature
range during the period between oil changes.
John Deere TURF-GARD
TM
is preferred. Also
recommended is John Deere PLUS-4
®
.
Other oils may be used if they meet one or more of the
following:
•API Service Classication SH
•API Service Classication SG
•CCMC Specication G4
•CCMC Specication G5
CHANGING ENGINE OIL
IMPORTANT: Change oil after rst 20 hours of operation
and every 100 hours thereafter.
1. Put unit on level surface.
2. Run engine a few minutes to warm oil.
3. Stop engine.
4. Remove oil ller cap (A) and drain plug (C) and drain oil into
container. Do not pollute, dispose of waste oil properly.
5. Install drain plug (C). Fill with oil to top of threads. Install
cap. Oil capacity is :
-HR-2500GH AND HR-2700GH: 0.6L (0.63 qts.)
DWG13-102299R0
-40°F
-22°F
-4°F
14°F
32°F
50°F
68°F
86°F
104°F
122°F
50°C
40°C
30°C
20°C
10°C
0°C
-10°C
-20°C
-30°C
-40°C
SAE 10W
-40
SAE 10W
-30
SAE 5W
-30
CHECK ENGINE OIL
NOTE: All washers are shipped with engine oil. Check
proper level.
1. Stop engine.
2. Place unit on level surface.
3. Remove oil ller cap/dipstick and wipe it clean.
4. Insert ller cap/dipstick into oil ller neck, but DO NOT
screw it in.
5. Remove dipstick. Proper oil level is at midpoint of
dipstick (A). Add oil if necessary to bring oil level to
top of threads (B).
6. Install and tighten cap.
PIC110-102299R0
P05-013107
B
C