Invacare 3600 Hot Tub User Manual


 
SECTION 1—GENERAL GUIDELINES
Part No 1118387 11 Side Entry Whirlpool Tub
Electrical
BecertainALLelectricalworkisperformedbyaqualifiedelectricianandisincompliance
withlocalelectricalcodes.
ALLelectricalconnectionsaretobewaterresistant.
Grounding
DANGER
Grounding is required. The unit should be installed by a qualified service
representative and grounded.
ƽ WARNING
The unit MUST be connected only to a supply circuit that is protected by a ground
fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and
should be tested on a routine basis. To test the GFCI, push the test button. The
GCFI should interrupt power. Push the resest button. Power should be restored. If
the GCFI fails to operate in this manner, GFCI is defective. If the GFCI interrupts
power to the bathtub without the test button being pushed, a ground current is
flowing, indicating the possibility of an electric shock. DO NOT use this hydro
massage bathtub. Disconnect the hydro massage bathtub and have the problem
corrected by a qualified service representative before using.
A GREEN-colored terminal (or a wire connector marked “G,” “GR,” “Ground,” or
“Grounding”) is provided within the terminal compartment. To reduce the risk of
electric shock, connect this terminal or connector to the grounding terminal of your
electric service or supply panel with a conductor equivalent in size to the circuit
conductors supplying this equipment.
Plumbing
Becertainallplumbingworkisperformedbyaqualifiedplumberandisincompliance
withlocalcodes.
Somestateandlocalplumbingcodesrequiretheinstallationofa“reducedpressurezone”
(RPZ)assemblyonboththeincominghotandcoldsupplylinestopreventbackflow
contaminationintothepotablewatersystem.Invacarerecommendsyouchecklocal
plumbingcoderequirementstodetermineifRPZsarerequiredonyourtubinstallation.
RPZsareNOTsuppliedbyInvacareandaretobeprovidedbythecustomerifrequired.
Whenoperatingwaterpressureexceeds55PSI,pressureregulators(similartothe¾inch
WattsU5)MUSTbeinstalled.
ThehotwatersupplytothetubMUSTnotexceed110°F(43°C)toprotecttheuserfrom
scalding.