Image IMHS40090 Hot Tub User Manual


 
10
The hydrotherapy spa is designed to seat four adults.
The eight jets provide a relaxing massage to sooth
away stress, and the strength of the water massage
can be adjusted by the air control. The hydrotherapy
spa holds 200 gallons of water and offers a heating
system (70¡F to 104¡F) and a filtration system.
The guidelines below explain how to properly use the
hydrotherapy spa. Follow these guidelines to maintain
the hydrotherapy spa for your long-term enjoyment.
PLUGGING IN THE HYDROTHERAPY SPA
Once the hydrotherapy spa is filled with water, the
power cord can be plugged in and the spa can be
turned on. Note: The first time the power cord is
plugged in, the spa will turn on automatically.
When connecting the power cord, plug the power cord
directly into a grounded circuit capable of carrying 15
or more amps. No other appliance should be on the
same circuit. Replace the power cord immediately if it
becomes damaged.
The power cord is equipped with a Ground Fault
Circuit Interrupter (GFCI), located at the end of the
power cord. You should always test the GFCI before
using the hydrotherapy spa.
First, turn on the hydrotherapy spa by pressing the
On/Off Switch on the console. Once the unit is run-
ning, press the GFCI ÒtestÓ button. The hydrotherapy
spa should shut off. Press the ÒresetÓ button. The
hydrotherapy spa should resume normal operation. If
the hydrotherapy spa continues to run after the ÒtestÓ
button is pressed, then the GFCI is damaged. Do not
use the hydrotherapy spa until the GFCI has been
repaired or replaced by a qualified electrician.
TESTING AND TREATING THE WATER
The hydrotherapy spa comes with a starter chemical
pack for maintaining the water in the spa. Disregard
the directions on the individual packages of ÒQUICK
pHix It DOWNÓ and ÒQUICK pHix It UP.Ó However, the
directions on the bottle of ÒNon-chlorine ShoxÓ and
ÒBromine BaseÓ are correct. Always keep the chemi-
cals away from children and pets.
The first time you use the spa, you should test and
treat the water. You must also treat the water each
time you refill the spa. Once you have verified that
the spa is functioning properly, and have allowed the
water to circulate for a while, you should remove the
spa cover and add 1/3 of the ÒBromine BaseÓ bottle,
and 1/3 of the ÒNon-chlorine ShoxÓ bottle to the water
in the spa. Allow the water to circulate for five min-
utes. You should now test the pH level of the water by
using the included test strips. Refer to the test strip
packaging for instructions on using the test strips. The
pH reading should be between 7.2 and 7.8.
If the level is too low, add half of one of the ÒQUICK
pHix It UPÓ packets to the water. Let the water circu-
late through the spa for five minutes. Test the pH level
again. Repeat until the pH level is correct.
If the level is too high, add half of one of the ÒQUICK
pHix It DOWNÓ packets to the water. Let the water cir-
culate through the spa for five minutes. Test the pH
level again. Repeat until the pH level is correct.
See WATER CHEMISTRY on page 14 for information
concerning proper water maintenance.
STARTING THE HYDROTHERAPY SPA
Once you have tested the GFCI, you should verify the
water flow from the pumping unit. Set the air control
on the console to the lowest setting (see USING THE
CONSOLE on page 12). The pumping unit will heat
the water as it pumps. Cover the hydrotherapy spa
with the spa cover. The spa cover must be tight
(see SECURING THE SPA COVER on page 11). The
water will heat at about 1.8¡F an hour with the cover
on. If you are using the hydrotherapy spa indoors,
and the room temperature is maintained at 70¡F, it will
take approximately 18 to 22 hours for the water to
reach the set temperature.
The temperature and water flow can be set or
changed by the controls on the console (see USING
THE CONSOLE on page 12).
Test and Reset
Buttons
Grounded circuit capable of
carrying 15 or more amps
GFCI
Using the Hydrotherapy Spa