SERVICE AND ADJUSTMENTS
HOOD
TO REPLACE HEADLIGHT BULB
• Raise hood.
• Pull bulb holder out of the hole in the backside of the
grill.
• Replace bulb in holder and push bulb holder securely
back into the hole in the backside of the grill.
• Close hood.
INTERLOCKS AND RELAYS
Loose or damaged wiring may cause your tractor to run
poorly, stop running, or prevent it from starting.
• Check wiring. See electrical wiring diagram in the
Repair Parts section.
TO REPLACE FUSE
Replace with 20 amp automotive-type plug-in fuse. The
fuse holder is located behind the dash.
TO REMOVE HOOD AND GRILL ASSEMBLY
(See Fig. 29)
• Raise hood.
• Unsnap headlight wire connector.
• Stand in front of tractor. Grasp hood at sides, tilt toward
engine and lift off of tractor.
• To replace, reverse above procedure.
ENGINE
TO AD JUST THROTTLE CON TROL CABLE
The throttle control has been preset at the factory and
ad just ment should not be necessary. If adjustment is
necessary, see engine manual.
TO AD JUST CARBURETOR
The carburetor has been preset at the factory and ad just ment
should not be necessary. However, minor ad just ment may be
required to compensate for differences in fuel, temperature,
altitude or load. If the carburetor does need adjustment,
see engine manual.
FIG. 29
HEADLIGHT WIRE
CONNECTOR
FIG. 28
HEX BOLT
KEPS NUT
POSITIVE
(RED)
CABLE
NEGATIVE
(BLACK)
CABLE
TERMINAL
GUARD
TERMINAL
ACCESS
DOOR
REPLACING BATTERY (See Fig. 28)
WARNING: Do not short battery ter mi -
nals by allowing a wrench or any other
object to contact both terminals at the
same time. Before connecting battery,
remove metal bracelets, wristwatch
bands, rings, etc.
• Lift hood to raised position.
• Remove terminal guard.
• Disconnect BLACK battery cable then RED battery
cable and carefully remove battery from tractor.
• Install new battery with terminals in same position as
old battery.
• Reinstall terminal guard.
• First connect RED battery cable to positive (+) battery
terminal with hex bolt and keps nut as shown. Tighten
securely.
Connect BLACK grounding cable to negative (-) bat tery
terminal with remaining hex bolt and keps nut. Tighten
securely
• Close terminal access doors.
• Close hood.
Positive terminal must be connected
rst to prevent sparking from ac ci -
den tal grounding.