Husqvarna RZ5424 Lawn Mower User Manual


 
LUBRICATION
54-Husqvarna
Engine Oil Levels
8011-500
Remove the dipstick
8009-159
The dipstick markings
WARNING!
Engine oil can be very hot if it is
drained directly after stopping the
engine. Allow the engine to cool to a
safe temperature before draining.
Check the oil level in the engine when the machine is
standing level and the engine is stopped.
Remove the dipstick, wipe it clean, and then replace it.
The dipstick should be screwed into place.
Take the dipstick out again and read the oil level.
The oil level should lie between the markings on the
dipstick. If the level is approaching the “ADD” mark, ll
the oil to the “FULL” mark on the dipstick.
Never ll to above the “FULL” mark.
The oil is lled through the hole for the dipstick.
API class SF, SG, SH, SJ or higher must be used.
Synthetic oil SAE 5W-30 or 10W-30 is recommended
at all temperatures. Mineral oil SAE 5W-30, 10W-30
can be used between -18 °C/0 °F and +5 °C/40 °F. At
temperature above +5 °C/40 °F single grade SAE 30
must be used.
See the Technical Data section for oil amounts.
Changing Engine Oil
The engine oil should be changed for the rst time
after 5-8 hours of operation. Thereafter, it should be
changed every 50 hours. The oil drain valve is located
on the left side of the unit, below the oil lter.
Place the machine on a at surface.
Place a container under the engine where the oil
drain valve exits.
Remove the valve cap.
Allow the oil to run out into the container.
Reinstall the oil drain valve cap.
Replace the oil lter if necessary.
Fill with new engine oil in accordance with
Checking the Oil Level.
Start the engine. Run it for 3-5 minutes. Stop and
recheck the oil level.
Transmission
The transmission is maintenance free and there is no
need for level checks or oil changes. If a leak occurs,
replace the unit or contact your Husqvarna dealer.