Husqvarna PZ29D CE Lawn Mower User Manual


 
CONTROLS
25
Fuel Shut Off Valve
The fuel shut off valve is located on the right front side
of the engine, below the air cleaner. The valve is off
when the handle tab is turned perpendicular to the
fuel line.
Fuses
Main harness fuses are located on the right hand side
of the machine under the seat. They are accessed by
tilting the seat forward. The right hand fuses are a 10
amp ATO/ATC fuse for accessory connections and
a 20 amp ATO/ATC fuse for the ignition switch and
safety interlock system
The engine harness has two fuses located near the
engine starter on the left side of the engine. The
engine harness fuses are a 30 amp Maxi fuse for the
fan reversing module and cooling fan and a 50 amp
Maxi fuse for the glow plugs.
8065-075
Main harness fuses located under the seat
8065-010
Fuel shutoff valve in the CLOSED position
8065-076
Release valve - left side
Pump Release Valves
Pump release valves are located on the right side of
each pump.
The valves must be engaged when pushing or pulling
the mower. See Moving Machine By Hand in the
Operation section.