Husqvarna 576XP AutoTune Chainsaw User Manual


 
MAINTENANCE
32 – English
use a muffler if the spark arrestor screen is missing
or defective.
The muffler is designed to reduce the noise level and to
direct the exhaust gases away from the operator. The
exhaust gases are hot and can contain sparks, which may
cause fire if directed against dry and combustible material.
Starter
Changing a broken or worn starter cord
Loosen the screws that hold the starter against the
crankcase and remove the starter.
Pull out the cord approx. 30 cm (12 inches) and hook it
into the notch in the rim of the pulley. Release the recoil
spring by letting the pulley rotate slowly backwards.
Undo the screw in the centre of the pulley and remove
the pulley. Insert and fasten a new starter cord to the
pulley. Wind approx. 3 turns of the starter cord onto the
pulley. Connect the pulley to the recoil spring so that the
end of the spring engages in the pulley. Fit the screw in
the center of the pulley. Insert the starter cord through
the hole in the starter housing and the starter handle.
Make a secure knot in the end of the starter cord.
Tensioning the recoil spring
Hook the starter cord in the notch in the pulley and
turn the starter pulley about 2 turns clockwise.
Note! Check that the pulley can be turned an additional
1/2 turn when the starter cord is pulled all the way out.
Changing a broken recoil spring
Lift off the pulley. See instructions under heading
Changing a broken or worn starter cord.
Remove the recoil spring from inside the pulley by
tapping the pulley lightly with its inside face
downwards against a work bench or the like. If the
spring pops out during fitting, wind it up again, working
from the outside in towards centre.
Lubricate the recoil spring with light oil. Fit the pulley
and tension the recoil spring.
!
WARNING! When the recoil spring is
wound up in the starter housing it is under
tension and can, if handled carelessly,
pop out and cause personal injury.
Care must be exercised when replacing
the return spring or the starter cord. Wear
protective glasses and protective gloves.
1 2
2
1