Husqvarna 240RJ Trimmer User Manual


 
20 English
MAINTENANCE
Cooling system
To maintain as low operating
temperature as possible the
engine is equipped with a
cooling system.
The cooling system consists
of:
1.An air intake on the starter
unit.
2.Cooling fins on the
flywheel.
3.Cooling fins on the
cylinder
4.Cylinder cover (leads cold
air onto the cylinder).
Clean the cooling system
using a brush at least once a
week, in difficult conditions
more often.
A dirty or blocked cooling
system leads to the engine
overheating resulting in
damage to the cylinder and
piston.
1
2
3
4
Muffler
NOTE!
Some mufflers are fitted with a catalytic converter. See
Technical data to see whether your machine is fitted with a
catalytic converter.
The muffler is designed to
dampen the noise level and
to direct the exhaust fumes
away from the user. The
exhaust fumes are hot and
can contain sparks, which
can result in fire if the
exhaust fumes are directed
towards a dry and
inflammable material. Some
mufflers are equipped with a
special spark arrest screen. If
your machine is fitted with
this type of screen it should
be cleaned regularly. This is
done using a wire brush. On
mufflers without a catalytic
converter the screen should
be cleaned weekly, or
replaced if necessary. On
mufflers fitted with a
catalytic converter the screen
should be checked and
cleaned monthly. If the
screen is damaged it should
be replaced. If the screen is
frequently blocked, this can
be a sign that the function of
the catalytic converter is
impaired. Contact your
dealer to inspect the muffler.
A blocked screen will cause
the engine to overheat
resulting in damage to the
cylinder and piston. Also see
under Maintenance.
NOTE!
Never use a machine with a defective muffler.
!
WARNING!
Mufflers fitted with catalytic converters
become extremely hot during use and
after stopping. This also applies at idling
speeds. Contact can result in burns to
the skin. Be observant to the risk of fire!
Spark plug
The condition of the spark
plug is affected by:
An incorrect carburetor
setting.
An incorrect fuel mixture
(too much or faulty oil).
A dirty air filter.
These factors cause deposits
on the spark plug electrode
that may result in
malfunction or starting
difficulties.
If the machine is low on power, difficult to start or runs
poorly while idling always check the spark plug first.
If the spark plug is dirty, clean it and at the same time check
that the electrode gap is 0.5 mm. The spark plug should be
changed after about one month of operation or earlier if
necessary.
NOTE! Always use the recommended type of spark plug. An
incorrect spark plug can damage the cylinder/piston.
0,5 mm