English – 23
MAINTENANCE
WARNING!
Procedures on contact with acid
External: Rinse well with plenty of water.
Internal: Drink large quantities of water or
milk. Contact a doctor as soon as
possible.
Eyes: Rinse well with plenty of water.
Contact a doctor as soon as possible.
Batteries emit explosive gas. Sparks, flames
and cigarettes must absolutely not be
brought into the vicinity of the battery.
!
Check the transmission’s oil level
Rider 13 H and Rider 13 H Bio
1. Lift off the transmission cover. Release the two
screws (one of each side) and lift off the trans-
mission cover.
Check the safety system
The machine is equipped with a safety system
which prevents starting the cutting unit or driving
the machine unless someone is sitting in the seat.
Check daily the safety system functions.
Check the level of the battery acid
Check that the level of the battery acid lies between
the markings. Top up the cells with
only
distilled
water.
2. Check that there is oil in the transmission oil
tank. Top up if necessary with engine oil SAE
10W/30 (class SF–CC).
This check is carried out by applying the parking
brake and raising the cutting unit into the transport
position. Start the engine and get off the machine.
When the cutting unit is lowered into the cutting
position the engine should stop.