Honeywell HW5500L Portable Generator User Manual


 
HW5500/HW5500E/HW5500EL/HW5500L Portable Electrical Generator Owner’s Manual www.honeywellgenerators.com 9
Assembly
Step 3: Install Handle Assembly
1. Hold handle bracket over pre-drilled holes on frame
as shown in Figure 12.
2. Attach bracket to frame using 40 mm flange-head hex
bolts and 10 mm flange serrated nuts and tighten.
3. Slide handle bar through center of each bracket and
line up bolt holes.
4. Attach handle to each bracket using 40 mm flange-
head hex bolt and 10 mm flange serrated nut to hole
closest to handle and tighten.
NOTE:
Handle should stick straight out after tightening bolts and
nuts. If handle seems to hang down, tighten bolts and
nuts further.
5. Attach chain to handle bracket as illustrated below.
Insert pin through bracket and handle.
6. Slide rubber handle grip onto each handle bar and
push to achieve snug fit.
Once properly installed, the handles can be collapsed, if
desired, by removing the pins.
To collapse handles, remove pins and push firmly
down on handle until it rests vertically against genera-
tor frame.
To return handles to horizontal position, pull up on
handle and lock with pins.
To install handle assembly, you will need:
Handle brackets (2)
Handle bars (2)
Pin and chain (2)
Rubber handle grips (2)
M6 X 40 X 8 mm flange-head hex bolts (6)
10 mm flange serrated nuts (6)
Socket wrench with 8 mm socket
*
* Not included
10 mm open end wrench*
FIGURE 12: Handle Bracket to Frame
FIGURE 13: Insert Handle Bar to Bracket
RUN
STOP
FIGURE 14: Attach pin and chain
Hands and fingers can be pinched from collapsible
handles.
Keep hands and fingers clear from hinges when
collapsing generator handles.
Handles should only be used to roll the generator to a
new location. If lifting the generator (i.e. into a vehicle),
never use the handles to support the complete weight
of the generator.
CAUTION