Homelite UT20003A Trimmer User Manual


 
Page 18
STO
P
O
P
1
2
3
MAINTENANCE
Spark Arrestor Cleaning Instructions:
Remove the spark arrestor from the muffler.
If your spark arrestor is made of a fiberglass material,
discard and replace.
If your spark arrestor is made of a metal material follow
these cleaning instructions:
1. Spray the spark arrestor with a quality carbon
cleaner.
2. Gently clean using a wire brush.
3. Install the new or cleaned spark arrestor and
reassemble completely before use.
REPLACING AND CLEANING AIR FILTER
See Figures 20 and 21.
For proper performance and long life, keep air filter clean.
1. Remove the air filter cover by pushing down on the
latch with your thumb while gently pulling on the cover.
2. Remove the filter, clean it in warm soapy water. Rinse
and let dry completely. For best performance, replace
annually.
3. Install the filter, align tabs, push in, and make sure the
latch snaps and latches into place.
FUEL CAP
WARNING:
A leaking fuel cap is a fire hazard and must be replaced
immediately.
The fuel cap contains a non-serviceable filter and a check
valve. A clogged fuel filter will cause poor engine perfor-
mance. If performance improves when the fuel cap is
loosened, check valve may be faulty or filter clogged.
Replace fuel cap if required.
SPARK PLUG
This engine uses a NGK # BPMR7A spark plug with
.025 in. (0.63 mm) electrode gap. Use an exact re-
placement and replace annually, or more frequently if
necessary.
STORING THE TRIMMER (1 MONTH OR
LONGER)
1. Drain all fuel from tank into a container approved for
gasoline. Run engine until it stops.
2. Clean all foreign material from the trimmer. Store it in a
well-ventilated place that is inaccessible to children.
Keep away from corrosive agents such as garden
chemicals and de-icing salts.
3. Abide by all Federal and local regulations for the safe
storage and handling of gasoline. Excess fuel should
be used up in other 2-cycle engine powered equip-
ment.
B
A
C
S
T
O
P
AIR FILTER
COVER
FILTER
Fig. 20
Fig. 21
STOP
A
B
C
LATCH
PULL COVER
TO OPEN