Homelite UT08934B Yard Vacuum User Manual


 
Page 11
OPERATION
PREMIUM EXACT MIX™ (50:1)
GASOLINE OIL
1 gallon (US) 2.6 oz.
1 Liter 20 cc (20 ml)
FILLING THE TANK
WARNING:
Always stop the engine before filling the fuel tank. Never
add fuel to a machine with a running or hot engine. Move
at least 30 ft. (9 m) from the refueling area before starting
engine. Do not smoke while filling the tank.
1. Clean the surface around the fuel cap to prevent con-
tamination.
2. Loosen the fuel cap slowly, by turning it counterclock-
wise.
3. Pour the fuel mixture carefully into the tank.
4. Clean and inspect the fuel cap gasket before replacing
the fuel cap.
5. Replace the fuel cap and tighten it by turning it clock-
wise.
6. Wipe spilled fuel from the product.
7. Move at least 30 ft. (9 m) away from refueling area
before starting the product.
NOTE: It is normal for smoke to be emitted from a new
engine during first use.
WARNING:
Check for fuel leaks. If you find any leaks, correct the
problem before using the product.
WARNING:
A leaking fuel cap is a fire hazard and must be replaced
immediately.
WARNING:
Gasoline is extremely flammable and explosive. A fire or
explosion from gasoline will burn you and others.
MIXING THE FUEL
This product is powered by a 2-cycle engine and requires
pre-mixing gasoline and 2-cycle oil. The mixture should be
at a 50:1 ratio, using Premium Exact Mix™ 2-cycle engine
oil. If Premium Exact Mix™ 2-cycle engine oil is not
available, use a high quality 2-cycle engine oil, mixed at a
50:1 ratio. See chart later in this section.
To mix the fuel:
1. Use a clean container that is approved for use with
gasoline.
2. Mix the Premium Exact Mix™ 2-cycle engine oil with
unleaded gasoline in the container, according to the
instructions on the oil package.
IMPORTANT:
This engine is certified to operate on unleaded gasoline
intended for automotive use with an octane rating of 87
([R + M] / 2) or higher. Do not use automotive oil or 2-cycle
outboard oil.
NOTE:
Premium Exact Mix™ fuel mixture will stay fresh up to 30
days. DO NOT mix quantities larger than usable in a 30 day
period.