Homelite UT08550 Blower User Manual


 
Page 16
SPARK PLUG
This engine uses a Champion RCJ6Y or equivalent spark
plug with .025 in. electrode gap. Use an exact replacement
and replace annually, or more frequently if necessary.
WARNING:
Be careful not to cross-thread the spark plug. Cross-
threading will seriously damage the product.
CLEANING THE EXHAUST PORT AND
MUFFLER
Depending on the type of fuel used, the type and amount
of lubricant used, and/or your operating conditions, the
exhaust port and muffler may become blocked with carbon
deposits. If you notice a power loss with your gas powered
tool, you may need to remove these deposits to restore
performance. We highly recommended that only qualified
service technicians perform this service.
VACUUM BAG
A dirty bag will reduce performance. To clean the bag, turn it
inside out and shake. Wash the bag in soapy water at least
once a year. To obtain a replacement bag, see How to Obtain
Replacement Parts on the back page of this manual.
SPARK ARRESTOR
The spark arrestor must be replaced every 25 hours or
yearly to ensure proper performance of the product. Spark
arrestors may be in different locations depending on the
model purchased. Please contact the nearest service dealer
for servicing your spark arrestor.
WARNING:
Never run the blower without the spark arrestor in place.
Failure to do so could result in a fire that could cause
serious personal injury.
MAINTENANCE
FUEL CAP
WARNING:
A leaking fuel cap is a fire hazard and must be replaced
immediately. Failure to do so could result in a fire that
could cause serious personal injury.
The fuel cap contains a non-serviceable filter and a check
valve. A clogged fuel filter will cause poor engine performance.
If performance improves when the fuel cap is loosened, the
check valve may be faulty or filter clogged. Replace the fuel
cap if required.
STORING THE PRODUCT
Clean all foreign material from the product. Store it in a
well-ventilated place that is inaccessible to children. Keep
away from corrosive agents such as garden chemicals and
de-icing salts.
Abide by all Federal and local regulations for the safe storage
and handling of gasoline.
When storing 1 month or longer:
Drain all fuel from tank into a container approved for
gasoline. Run engine until it stops.