I.C.T.C. Holdings Corporation PW2424-LD Pressure Washer User Manual


 
H.E.R.O. Industries Pressure Washer Owners
Page 5
11. At this point, the gun is triggered to evacuate any remaining air in the system. Then trigger the
gun and begin turning the red unloader knob in a clockwise direction as far as it will turn. You
should now have full pressure.
12. To introduce chemicals/detergent to the spray, do the following;
a. Install “Black” injector tip.
b. Attach the chemical / detergent line to the fitting marked “Chem” and place the filter end into the
chemical or detergent container.
c. Trigger the SPRAY GUN and chemical / detergent should start to flow out of gun.
1. Trigger the spray gun and reduce the pressure by turning the unloader knob counter-clockwise.
2. Turn engine switch to the OFF position.
3. Turn the throttle and gas levers to the OFF or Closed positions
.
4. Shut OFF the water.
5. Trigger gun to remove any remaining pressure in the system.
6. Disconnect hose.
START-UP AND OPERATION INTRODUCTION
SHUTTING DOWN THE MACHINE AFTER USE
For your convenience, we have provided a selection of nozzles to choose from.
Your machine is equipped with a 0°, 15°, 40°, and a chemical nozzle.
If you require a different cleaning action, we suggest selecting the correct tip for the job.
1. RED = 0° Angle - High impact, solid stream.
2. YELLOW = 15° Angle - Narrow width spray pattern.
3. WHITE = 40° Angle - Wide width spray pattern.
4. BLACK = Chemical Injector
0° Angle 15° Angle 40° Angle
NOZZLE SELECTION