Hayward Pools ISCC100 Swimming Pool Filter User Manual


 
XStream™ Filtration Series __________ _____________________________________
NOTE: The National Electrical Code (NEC) permits use of a cord with a maximum 3 ft.
(1 m) length. If your pump is equipped with a cord complying with the NEC, the following three
(3) items apply.
WARNING Risk of Electric Shock. Connect only to a grounding
type receptacle protected by a Ground Fault Circuit Interrupter (GFCI). Contact a
qualified electrician if you cannot verify that the receptacle is protected by a
GFCI.
WARNING To reduce the risk of electric shock replace damaged cord
immediately. Do NOT bury cord. Locate cord to minimize abuse from lawn
mowers, hedge trimmers and other equipment.
WARNINGTo reduce the risk of electric shock, do NOT use an extension cord to
connect unit to electric supply. Provide a properly located outlet. Qualified personnel MUST do
all electrical wiring.
CAUTIONAll suction and discharge valves MUST be OPEN when
starting the filter system. Failure to do so could result in severe personal injury
and/or property damage. All drains and suction covers MUST have properly
installed covers securely attached with the screws supplied with the covers. If
screws are lost, order replacement parts from your supplier.
DANGERSuction Entrapment Hazard. Never use the pool or
spa if a drain cover is damaged, cracked, missing, or not securely attached. Suction in drains and
suction outlets can cause drowning, disembowelment, hair or body entrapment, severe injury, and
death. Disembowelment, entrapment, or drowning is possible when body parts or hair come in
contact with damaged, broken, cracked, missing, or unsecured drain covers and suction outlets.
Suction from pumps with only one drain or suction outlet can cause disembowelment,
entrapment, or drowning. Pumps for pools and spas require two (2) functioning suction outlets at
least three (3) feet apart, on two (2) walls or on the floor and one (1) wall of the pool or spa.
Installation of pump and suction outlets must be in compliance with all applicable local building
codes. Replace damaged, broken, cracked, missing, or unsecured drain covers and suction outlets
immediately.
WARNINGHazardous Pressure. Pumps, filters, and other
equipment/components of a swimming pool filtration system operate under pressure. Incorrectly
installed and/or improperly tested filtration equipment and/or components may fail resulting in
injury and/or property damage. A qualified pool professional MUST conduct all pressure tests.
This product is intended for above-ground/on-ground swimming pool applications only. Do NOT
connect to a high-pressure system such as a municipal water main. To prevent explosion caused
by entrapped air in the filtration system use provided air relief valve to bleed air from the system.
Confirm that ALL filtration system component clamps, bolts, and covers have been tightened to
the manufacturer’s recommendations.
WARNINGNever operate or test the filtration system at more than 30 PSI.
SAVE THESE INSTRUCTIONS