12 Volt DC Fuse (8): 8. The 12 Volt DC Outlet has one Fuse (8) to protect the Genera-
tor from overloading. The Generator is equipped with the following size and type of
Fuse: F10A250V. Should a 12 VDC output exceed the fuse’s rating, always check
to see if the Fuse has “blown” (a melted filament within the Fuse). If necessary,
unplug all electrical loads from the Generator, replace with a new Fuse, and reat-
tach a reduced load to the generator. (See Figure D.)
Power-On Light (10): 9. Indicates voltage is being provided by the Generator.
(See Figure D.)
PRE-START INSTRUCTIONS
To Add Engine Oil:
CAUTION! 1. Your warranty is voided if you do not put engine oil in the Engine’s
crankcase prior to its first use. Before each use, check the oil level. Never run the
Engine with low or no engine oil. Running the engine with low or no oil will perma-
nently damage the Engine.
OIL DIPSTICK
(65A)
FUEL TANK
(31)
FUEL GAUGE
(35)
FUEL FILTER
(32)
FUEL TANK CAP
(34)
FIGURE E
2. The Engine MUST be filled with a high quality grade engine oil. If the Engine will
be run in temperatures above 32 degrees Fahrenheit, use SAE 30 weight oil. If the