Harbor Freight Tools 69728 Portable Generator User Manual


 
Item 69728 / 69729
Page 11
For Pump technical questions, please call 1-800-444-3353.
For Engine technical questions, please call 1-800-520-0882.
SAFETYOPERATIONMAINTENANCE SETUP
Connecting Electrical Loads
Familiarize yourself with the engine controls, power panel and how to start the engine before using the generator.
Calculate the wattage of the products you will use with the generator and verify that the generator can handle the
total load.
WARNING! Connect only properly wired plugs to the generator.
A plug that is spliced onto a different cord may be hazardous.
Only a qualied electrician should wire a plug onto a cord.
CAUTION Never exceed the rated capacity for this Generator,
as serious damage to the Generator and/or appliances, tools, and
equipment could result from an overload. Starting and running
wattage requirements should always be calculated when matching this
Generator’s wattage capacity to the appliance, tool, or equipment.
Use the DC12V Receptacle to power 12VDC equipment.
WARNING! Do not charge batteries without a proper charge controller. Do not overcharge.
a. Connect the items that require the most wattage rst.
b. Connect “inductive” load appliances, tools, and equipment next.
Inductive loads are small hand tools and some small appliances.
c. Connect any lights next.
d. Voltage sensitive appliances, tools, and equipment should be the last to be connected to the Generator.
Plug voltage sensitive items such as TV’s, DVD players, microwaves, and cordless telephones into a UL®
Listed voltage surge protector (not included). Then, connect the surge protector into the Generator.
IMPORTANT! Failure to connect and operate appliances, tools, and equipment in this sequence can cause
damage to the Generator, appliances, tools, and equipment and will void the Warranty of this Generator.
NOTE: If Engine speed or voltage uctuates with a load below the Generator’s rated watts, move the Engine Choke
Lever to the “HALF-CHOKE” position.
Evenly distributed
over outlets:
IF ANY CIRCUIT BREAKERS TRIP CHECK THE FOLLOWING:
1. Make sure that ALL circuit breakers are reset
before starting the generator again.
2. Adjust the plugs so the loads are
shared across outlet circuits.
To achieve rated output from the generator,
distribute loads over outlets.
t
0)
1,
000
400
)
200
6
00)
600
To
ta
l R
u
n
n
in
g
Watts
(m
u
s
t b
e
le
s
s
th
a
n
3
,2
0
0
)
2,200
e
s
t
A
d
d
itio
n
a
l S
ta
rt-u
p
Wa
tts
600
t
u
p
Wa
tts
n
e
e
d
e
d
fo
r a
ll lo
a
d
s
(m
u
s
t b
e
le
s
s
th
a
n
4
,0
0
0
)
2,800