Great Dane GDB10029 Lawn Mower User Manual


 
Service Electrical - 23
SERVICE ELECTRICAL
M71044
A - Booster Battery
B - Disabled Vehicle Battery
1. Connect positive booster cable to booster battery (A)
positive post (C).
2. Connect the other end of positive booster cable to the
disabled vehicle battery (B) positive post (D).
3. Connect negative booster cable to booster battery
negative post (E).
4. Connect the other end (F) of negative booster cable to a
unpainted metal part of the disabled machine’s engine,
away from battery.
5. Start the engine of the disabled machine and run
machine for several minutes.
6. Carefully disconnect the booster cables in the exact
reverse order: negative cable first and then the positive
cable.
Replacing Fuses
The machine is equipped with two 20-amp fuses (electric
start units) and one 20-amp fuse (manual start units) to
protect the electric start and/or charging circuit. These
fuses are located under the control panel area.
1. Remove defective fuse from socket.
2. Check metal clip in fuse window and discard fuse if clip
is broken.
3. Install new fuse into socket.
c CAUTION: Avoid injury! The battery produces a
flammable and explosive gas. The battery may
explode:
Do not attempt to jump start a frozen battery.
Warm to 16 degrees C (60 degrees F).
Do not smoke near battery.
Wear eye protection and gloves.
Keep sparks and flames away.
Do not connect the negative (-) booster
cable to the negative (-) terminal of the
discharged battery. Connect at a good ground
location away from the discharged battery.
Do not cross jump the battery, damage to
electronic modules will result.
B A
E
C
D
F
IMPORTANT: Avoid damage! When replacing fuses -
use only 20-amp fuses or you may damage the
circuit.