Graco 2730B Pressure Washer User Manual


 
Operation
6 309286K
Operation
Pressure Relief Procedure
Follow this procedure when you stop spraying and
before cleaning, checking, servicing or transporting
equipment.
1. Engage trigger lock.
2. Turn pressure washer OFF.
3. Remove ignition cap from spark plug.
4. Turn off water supply and disconnect pressure
washer from water.
5. Unlock trigger lock. Trigger gun to relieve pressure.
Engage trigger lock.
TIA
ti5424a
ON
OFF
If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved after fol-
lowing the pressure relief procedure, VERY
SLOWLY loosen tip guard retaining nut or hose end
coupling to relieve pressure gradually, then loosen
completely. Clear hose or tip obstruction.
ti5425a
ti5427a