Graco 3000 psi Pressure Washer User Manual


 
2 308524
Table of Contents
Warnings 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setup 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pressure Relief Procedure 5. . . . . . . . . . . . . . . . . . . . . . .
Pump Service 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pressure Washer Parts Drawing and List 10. . . . . . . . .
Pump Parts Drawing and List 12. . . . . . . . . . . . . . . . . . .
Troubleshooting 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Standard Warranty 16. . . . . . . . . . . . . . . . . . . . . .
Graco Phone Number 16. . . . . . . . . . . . . . . . . . . . . . . . . .
Symbols
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
instructions.
D Do not point the gun at anyone or at any part of the body.
D Fluid injected into the skin may look like just a cut, but it is a serious injury. Get emergency
medical attention.
WARNING
WARNING
INJECTION HAZARD
Spray from the gun, leaks or ruptured components can inject fluid into your body and cause serious
injury. Fluid splashed in the eyes or on the skin can also cause serious injury.
D Do not stop or deflect leaks with hand, body, glove, or rag.
D Do not put your hand or fingers over the spray tip.
D Tighten fluid connections before you start this equipment.
D Engage the gun trigger safety when you stop spraying.
D Follow Pressure Relief Procedure on page 5 if the spray tip clogs and before you clean,
check, or service this equipment.
D Repair or replace worn or damaged parts immediately.
D Check hoses, tubes, and couplings daily. Do not repair high-pressure couplings; you must replace
the entire hose. Fluid hoses must have spring guards on both ends to prevent kinks and rupture.