GenTran 6370C Portable Generator User Manual


 
Mounting Instructions for Model 6370C Parallel Power Kit
For Honda E3000i Generators Only
5
STEP 5
Insert short Parallel Cables into “Parallel Operation”
jacks on the first generator. Do not be concerned with
polarity when connecting to these outlets, as the
polarity is handled by the internal computer chip within
the EU3000i. Then attach the first green/yellow ground
cable to grounding stud on the lower right side of the
first generator using a screwdriver.
GROUND
STEP 6
Insert the set of longer Parallel Cables into “Parallel Operation” jacks
on second generator. Attach green/yellow ground cable to grounding
stud on the lower right side of the second generator as well.
During operation, if the Parallel Power Kit is not feeding power to
your load when generators are running, it is possible that the circuit
breaker has been tripped. You will need to reset circuit breaker on
the front of the Parallel Power Kit to “ON”.
Be sure to shut down generators before connecting to or
disconnecting from Parallel Power Kit.
For 120 volt applications ONLY.
6
NOTE: To use your paralleled
generators to provide backup
power to a home or other
dwelling, or an RV, you will need
an adapter cord to run from the
Parallel Power Kit (use 10/3 or
10/4 cord) with an appropriate
female connector to plug into your
power inlet box, transfer switch or
RV. A transfer switch is required
by the National Electrical Code
Article 702.6 for all backup
generator installations.
P.O. Box 1001, Alpharetta, GA 30009
Toll Free: 1-888-GEN-TRAN
www.gen-tran.com
PN 511759 Rev A
WARNING: Hazardous voltages present when generators running. Will cause death, serious injury or substantial property damage. Shut
off generators before connecting to or disconnecting from Parallel kit. IMPORTANT: The accessories noted here are intended for 120 volt
use only. Transfer switches and power inlet boxes should be installed by a qualified professional familiar with residential wiring and
electrical codes. Gen/Tran accepts no responsibility for accidents caused by incorrect or in appropriate installation or use of this product.
Transfer Switch
GenTran Model
300660
or
301060
30 Amp 125V
Power Inlet Box
GenTran 05302
Or
30 amp 125/250V
Power Inlet Box
GenTran 14302
REQUIRES
Male Plug
50 amp 125 V
GenTran Part
RJBP6361
Honda Code
6363550
** Use 10/4 or
10/3 Cord **
CORD REQUIRES
Female Conn.
GenTran Part
RJBC530
or
RJBC1430
Depending on transfer
switch or power inlet
box model
CIRCUIT BREAKER
DO YOU NEED A TRANSFER SWITCH
OR OTHER ACCESSORIES?